Jacuzzi® Spas - PWA LCD 60Hz Single Speed, J-400 models 2008 and later (J400 60Hz JWB 6600-098) - 6600-728
New Part Number: 6600-728
Replacement option for:
AI# SD6600-098 MFG# 6600-098
AI# SD6600-161 MFG# 6600-161
AI# SD6600-180 MFG# 6600-180 880 Series 2005-2010 OR if Pump 1 is 1 Speed
6600-161 Sundance®Spas Circuit Board, 2005-4/2009 880 NT Systems, 1 and 2 Pump with PermaClear 6600-161, 6600-098 (old part number with eprom 9.51A , which is now being replaced by the 6600-161, 9051B). Eprom 9.51B or IC Processor 2.0A included Used on: Cameo, Optima, Majesta, Altamar, Marin, and Capri (started approx. Spring 2008) 1. 2011 Boards could have either an Erpom or IC Processor. Visually inspect to see what board is needed.2. Majesta, Altamar, Marin, Capri started approx. Spring 20083. Cannot be used in place of the 6600-1804. Can be used in place of the 6600-098 which is obsolete. Cameo, Optima, Majesta, Altamar, Marin, and Capri (started approx. Spring 2008) Jacuzzi® Spas, 6600-161, 6600-098 (old part number) Jacuzzi® Spas LCD J-400 2008+. Replaces the 6600-098 Circuit Board. Old Eprom was 9.51A, new Eprom 9.51 B. 6600-161*, 2008-4/09 880 NT systems, 1- and 2-pump with PermaClear used on (EPROM 9.51B included). Fits all Jacuzzi J-400 models 2008 and later.
*Replaced 6600-098, which as was for spas and hot tubs 2005 to February 2008. Board memory changed from a Eprom/Dallas Chip to a Microprocessor style in early February 2011+. Both board types are fully interchangeable. This circuit board was used on Sundance® 880 series with water fall from 2005 to Feb 2008. Otherwise, spas after Feb 2008 would need 6600-161 (this circuit) or 6600-164. You will need to look at your old board to determine the right circuit board.
Jumper settings are as follows:
JP19 Jumper Bank
JP19-1 - On - Celcius, Off - Fahrenheit
JP19-3 - On - 50Hz, Off - 60Hz
JP19-5 - On - LED Lights, Off - Incandescent Lights
JP19-7, 9, and 11 are not used
JP9 Jumper Bank
JP9-1 - On - Enables Trouble Log, Off - Disables Trouble Log
JP9-3 - On - Enables ILOC, Off - Disables ILOC
JP9-5 - NOT USED
JP9-7 - On - 60A Logic Allows 2 Pumps on w/Heater, Off - 50A Logic Forces Heater Off When More Than 1 Pump is ON
JP9-9 - On - Enables Pump 2 on -728/-730 pcb's and Pump 3 on -392 pcb, Off - Disables
JP9-11 - On - 40A Logic Forces Heater off w/ Any Pump in Hi, Off - Disables
JP9-13 - On - Allows Only 1 Pump w/Blower to Operate at a Time, Off - Blower, Pump 1, Pump 2 Can Operate at the Same Time
JP9-15 - On - Recall All Factory Settings, Off - The Jumper Must Remain Off During Normal Operation
For Sundance Spas (2005-2010) This board operates a circulation pump and (2) 1-speed pumps.
For Jacuzzi Spas (2006-2009) J-460, J-465, J-470, and J-480, this board operates (2) 1-speed pumps. J-300 series LCD models also operate (2) 1-speed pumps.
| System | Year | Details/Models |
| J-400 LCD | 2006 Mid 12/2009 | J-480, J-470, J-465, J-460 |