Blu Water Technology - Electrode Replacement, BluWater Blu Fusion, Helix - E-200
Please note that this replacement cell does not include the bards or clamps. Please add the barbs or clamps needed to your order separtely:
Replaces: 386870, ISISELECTRODE
Technical Notes:
When the spa is circulating, power flows to the ISIS unit and current is generated at the electrode cell. The electrolytic process happens in the flow-through cell, which converts TRU-BLU sodium bromide or bromine salt into Bromine.
When operating correctly and the spa is circulating, the readout on ISIS Logix Controller is displayed. Pressing up and down keys on controller for 3 seconds shows conductivity. A reading should be between 0.5 and 1.5 which shows that there is conductivity in the cell. Test spa water for Bromine for an ideal range is between 3 and 5 PPM to assure ISIS is working properly.
If error code OE or Open Element appears, the controller may have detected an inadequate connection to the electrode cell.
This can happen after installation if the electrode is not connected properly or salt has not yet been added to the spa water.
If the OE notification code appears after extended use of your spa operating the ISIS bromine salt system and cell unit, this might be the result of calcium build up on the electrode from poor water chemistry or other cell degradation.
| Manufacturer | BluWater Technology |
| Model | Blu Fusion, ISIS |
| Voltage | 115v/230v |
| Generator Part Type | Electrode |