Sundance® Spas - Circuit Board 6600-726, w/Circ Pump Only, LX-15, Sweetwater - 6600-726
This board operates a circulation pump. If the spa does not have a circulation pump, then use: 6600-720
Jacuzzi®/Sundance®/Sweetwater Circuit Board w/Circ Pump Only, LX-15. Used on Sundance Spas and Jacuzzi Spas. Replaces, 6600-046 (with circ pump eprom), 6600-088, 6600-288, 6000-167. Comes with latest Eprom Revision 3.61+.
Replacement Option For:
AI #SD6000-167 / MFG # 6000-167
AI #SD6600-288 / MFG # 6600-288 PCB:780 R3.56 and LX-15 with Circ
AI #SD6600-088 / MFG # 6600-088 PCB:780 R3.56
Need to replace your Hi-Limit and Temp Sensor as well?
Hi-Limi: 6600-068
Temp Sensor: 6600-166
Revisions: R6.16, R6.17, R3.54, R3.56 WITH CIRC PUMP
Sweetwater Spas Circuit Board: P/N 6600-288
This board supports a circulation pump. If you do not have a circulation pump, then use board number 6600-287
With circulation pump Rev 3.54. Palermo, Bahia, and Cayman 6600-088 is now 6600-288 Sundance® 2003 + Palermo, Bahia, and Cayman
Also used in Jacuzzi® Models: J-320 - J-330 - J-340
Jumper settings are as follows:
Jumper 2 - On 1 Pin - 15A, On 2 Pins - 50A
Jumper 4 - On 1 Pin - 2 pumps, On 2 Pins - 1 pump
Jumper 6 - Used along with Jumper 2
Jumper 8 - On 1 Pin - Celsius temp display, On 2 Pins - Fahrenheit temp display

Programming:
Circ Pump - Press and hold Jet 1 and minus key for 3 seconds. You will see c1, c2, c3, or c4. Hit plus or minus key to select. They are in 4 hour increments. For example, C1 runs for 4 hours and C2 runs for 8 hours, and so on. Hit Jet 1 to lock it in when you've made your selection.
2 Speed, Pump 1 - To Program low speed, press and hold arrow up and arrow down at the same time for 3 seconds. Selections can be made for f1, f2 and f3. F1 means it will run for half and hour twice a day. F2 run a half hour three times a day. F3 runs 4 times a day, 30 mins at a time.
6600-288 Rev. 3.57+ Circuit Board used on the following Sundance®, Sweetwater, Jacuzzi Spas: 6600-288
Circuit Board is for the following Sundance® and Sweetwater Spas models: A. 2008+ 1-pump 680 Burlington model equipped with a circulation pump B. 2007+ 680 Hartford and Hawthorne models Equipped with a Circulation Pump C. 2007+ 780 Hamilton, Chelsee, Certa and Camden (1-pump) D. 2005-2006 780 Series Sundance® Spas (Palermo, Bahia, Cayman) E. 2003-2005 Sweetwater Board (Palermo, Bahia, and Cayman) F. Replaces the 6600-087and 6600-088 Board 3.56, for circulation pump systems.
If your system has a 6600-087 and the eprom chip that begins with a 5 (such as REV 5.54), then you have a 6600-287 board. 2002+ Jacuzzi® Circuit Board for: J-300 Series LED Circuit Board 6600-288 is for following models: 1. 2002-2006 J-335, J-345, 2005-2006 J-325 2. 2002-2003 J-325, 3.2007 J-325 (240 Volt Model). As of 2007 the J-300 Series are all LED models. 4. 2007+ J-365, J-355, J-345, J-335 5. 2008+ J-375 This board (6600-288) is for circulation pump systems (see 6000-125 for circulation pump). Comes with a Series 3.61+ chip. If your circuit board has a Software Chip that begins with a 3, then this is the correct series board. Sundance has revised this chip several times If you have an older board without a Circulation pump, then you need a board with a Series Chip that starts with a 5.
If you have an older board WITHOUT a Circulation pump (see 6000-125 for picture of circulation pump), then you need a board with a Series Chip that starts with a 5. This would be a 6600-287 board. ALL 6600-287, 6600-087 boards (without circulation pump logic, Chip 5.54) and 6600-288, 6600-088 (with Circulation Pump Logic, Chip 3.56 or higher) are identical but use different microchips.
Replacement Option For:
AI # SD6000-167 / MFG 6000-167
AI# SD6600-288 / MFG 6600-288
PCB:780 R3.56 and LX-15 with Circ
AI# SD6600-088 / MFG 6600-088
PCB: 780 R3.56